Primarily used for overhead service applications such as street lighting, outdoor lighting, and temporary service for construction. The webpage specifies a rated voltage of 0.6/1 kV and a maximum conductor temperature of 90°C for cross-linked polyethylene (XLPE)-insulated conductors.
Conductor: stranded, circular compacted or circular compressed AAC or AAAC. Insulation: black cross-linked polyethylene (XLPE), weather-resistant and UV-resistant.
NFC 33-209 Insulated cable assembled with harness for overhead networks, rated voltage 0.6/1 kV.
Conductor Function | Nominal Section (mm²) | No. of Wires | Max. DC Resistance at 20°C (Ω/km) | Conductor Diameter Min. (mm) | Conductor Diameter Max. (mm) | Breaking Force Min. (daN) | Insulation Thickness (mm) | Core OD Min. (mm) | Core OD Max. (mm) |
Phase / Neutral / Public lighting | 16 | 7 | 1.91 | 4.6 | 5.1 | 190 | 1.2 | 7.0 | 7.8 |
Phase / Neutral / Public lighting | 25 | 7 | 1.20 | 5.8 | 6.3 | 300 | 1.4 | 8.6 | 9.4 |
Phase / Neutral / Public lighting | 35 | 7 | 0.868 | 6.8 | 7.3 | — | 1.6 | 10.0 | 10.9 |
Phase / Neutral / Public lighting | 50 | 7 | 0.641 | 7.9 | 8.4 | — | 1.6 | 11.1 | 12.0 |
Phase / Neutral / Public lighting | 70 | 12 | 0.443 | 9.7 | 10.2 | — | 1.8 | 13.3 | 14.2 |
Phase / Neutral / Public lighting | 95 | 19 | 0.320 | 11.0 | 12.0 | — | 1.8 | 14.6 | 15.7 |
Phase / Neutral / Public lighting | 120 | 19 | 0.253 | 12.0 | 13.1 | — | 1.8 | 15.6 | 16.7 |
Phase / Neutral / Public lighting | 150 | 19 | 0.206 | 13.9 | 15.0 | — | 1.8 | 17.3 | 18.6 |
Neutral | 54.6 | 7 | 0.63 | 9.2 | 9.6 | 1660 | 1.6 | 12.3 | 13.0 |
Neutral | 70 | 7 | 0.50 | 10.0 | 10.2 | 2050 | 1.6 | 12.9 | 13.6 |
Neutral | 95 | 19 | 0.343 | 12.2 | 12.9 | 2750 | 1.6 | 15.3 | 16.3 |
Pilot | 1.5 | 1 | 12.1 | — | — | — | 1.2 | 3.7 | 4.2 |
No. of Cores × Section (mm²) | No. of Wires | Nominal Insulation Thickness (mm) | Approx. Cable Diameter (mm) | Max. DC Resistance at 20°C (Ω/km) | Approx. Weight (kg/km) |
2×16 | 7 | 1.2 | 14.4 | 1.91 | 131 |
2×25 | 7 | 1.4 | 17.6 | 1.20 | 200 |
2×35 | 7 | 1.6 | 20.4 | 0.868 | 273 |
2×50 | 7 | 1.6 | 22.6 | 0.641 | 350 |
2×70 | 12 | 1.8 | 26.8 | 0.443 | 495 |
2×95 | 19 | 1.8 | 30.4 | 0.320 | 656 |
2×120 | 19 | 1.8 | 32.8 | 0.253 | 799 |
4×16 | 7 | 1.2 | 17.4 | 1.91 | 262 |
4×25 | 7 | 1.4 | 21.3 | 1.20 | 399 |
4×35 | 7 | 1.6 | 24.7 | 0.868 | 547 |
4×50 | 7 | 1.6 | 27.3 | 0.641 | 699 |
4×70 | 12 | 1.8 | 32.4 | 0.443 | 990 |
4×95 | 19 | 1.8 | 36.8 | 0.320 | 1311 |
4×120 | 19 | 1.8 | 39.7 | 0.253 | 1597 |
Configuration (mm²) | Phase Wires | Neutral Wires | Phase Insulation (mm) | Neutral Insulation (mm) | Approx. Cable Diameter (mm) | Phase Max. DC Resistance (Ω/km) | Neutral Max. DC Resistance (Ω/km) | Approx. Weight (kg/km) |
1×25 + 1×54.6 | 7 | 7 | 1.4 | 1.6 | 21.3 | 1.20 | 0.63 | 309 |
1×35 + 1×54.6 | 7 | 7 | 1.6 | 1.6 | 22.7 | 0.868 | 0.63 | 345 |
1×50 + 1×54.6 | 7 | 7 | 1.6 | 1.6 | 23.8 | 0.641 | 0.63 | 384 |
1×70 + 1×54.6 | 12 | 7 | 1.8 | 1.6 | 25.9 | 0.443 | 0.63 | 456 |
1×95 + 1×54.6 | 19 | 7 | 1.8 | 1.6 | 27.7 | 0.320 | 0.63 | 537 |
1×70 + 1×70 | 12 | 7 | 1.8 | 1.6 | 26.7 | 0.443 | 0.50 | 491 |
1×95 + 1×70 | 19 | 7 | 1.8 | 1.6 | 28.5 | 0.320 | 0.50 | 571 |
1×120 + 1×70 | 19 | 7 | 1.8 | 1.6 | 29.7 | 0.253 | 0.50 | 643 |
1×120 + 1×95 | 19 | 19 | 1.8 | 1.6 | 31.9 | 0.253 | 0.343 | 737 |
1×150 + 1×95 | 19 | 19 | 1.8 | 1.6 | 33.6 | 0.206 | 0.343 | 819 |
3×25 + 1×54.6 | 7 | 7 | 1.4 | 1.6 | 23.5 | 1.20 | 0.63 | 508 |
3×35 + 1×54.6 | 7 | 7 | 1.6 | 1.6 | 26.1 | 0.868 | 0.63 | 619 |
3×50 + 1×54.6 | 7 | 7 | 1.6 | 1.6 | 28.1 | 0.641 | 0.63 | 733 |
3×70 + 1×54.6 | 12 | 7 | 1.8 | 1.6 | 31.9 | 0.443 | 0.63 | 951 |
3×95 + 1×54.6 | 19 | 7 | 1.8 | 1.6 | 35.2 | 0.320 | 0.63 | 1192 |
3×70 + 1×70 | 12 | 7 | 1.8 | 1.6 | 32.4 | 0.443 | 0.50 | 986 |
3×95 + 1×70 | 19 | 7 | 1.8 | 1.6 | 35.6 | 0.320 | 0.50 | 1227 |
3×120 + 1×70 | 19 | 7 | 1.8 | 1.6 | 37.8 | 0.253 | 0.50 | 1441 |
3×120 + 1×95 | 19 | 19 | 1.8 | 1.6 | 39.1 | 0.253 | 0.343 | 1536 |
Configuration (mm²) | Phase Wires | Neutral Wires | Street-Light Wires | Phase Insulation (mm) | Neutral Insulation (mm) | Street-Light Insulation (mm) | Approx. Cable Diameter (mm) | Phase Resistance (Ω/km) | Neutral Resistance (Ω/km) | Public-Lighting Resistance (Ω/km) | Approx. Weight (kg/km) |
3×25 + 1×54.6 + 1×16 | 7 | 7 | 7 | 1.4 | 1.6 | 1.2 | 30.1 | 1.20 | 0.63 | 1.91 | 571 |
3×35 + 1×54.6 + 1×16 | 7 | 7 | 7 | 1.6 | 1.6 | 1.2 | 32.9 | 0.868 | 0.63 | 1.91 | 682 |
3×50 + 1×54.6 + 1×16 | 7 | 7 | 7 | 1.6 | 1.6 | 1.2 | 35.1 | 0.641 | 0.63 | 1.91 | 797 |
3×70 + 1×54.6 + 1×16 | 12 | 7 | 7 | 1.8 | 1.6 | 1.2 | 39.3 | 0.443 | 0.63 | 1.91 | 1014 |
3×70 + 1×54.6 + 1×25 | 12 | 7 | 7 | 1.8 | 1.6 | 1.4 | 39.3 | 0.443 | 0.63 | 1.20 | 1049 |
3×70 + 1×70 + 1×16 | 12 | 7 | 7 | 1.8 | 1.6 | 1.2 | 40.1 | 0.443 | 0.50 | 1.91 | 1049 |